Stimulating Echogenic Needle - 21Ga X 10cm (4in) For Use With Stimpod
Log in for pricing
The Stimpod™ Peripheral Nerve Block and Neuromuscular Monitoring System is designed to support both regional anesthesia and general anesthesia applications. For regional anesthesia, the Stimpod™ can be used for cutaneous nerve mapping with the Nerve Mapping Probe and for nerve localization using stimulating needles to facilitate peripheral nerve block procedures. For general anesthesia, the Stimpod™ can be used with noninvasive surface electrodes to assess the efficacy of neuromuscular blocking agents through objective neuromuscular monitoring. Real-time visual and audible feedback, waveform display, and customizable stimulation parameters help clinicians accurately identify nerves and monitor neuromuscular function.
- Designed for peripheral nerve block procedures and neuromuscular monitoring
- Supports both regional anesthesia and general anesthesia applications
- Regional anesthesia applications include nerve mapping and nerve localization
- General anesthesia applications include assessment of neuromuscular blockade using surface electrodes
- Adjustable stimulation current, pulse width, and twitch frequency
- Visual and audible feedback help identify probable nerve proximity
- Real-time waveform display of delivered stimulation currents
- Pause mode allows stimulation parameters to be adjusted without delivering stimulation
- Non-linear current adjustment for enhanced control
- User-programmable memory stores up to 20 current and pulse width settings
- Compatible with Stimpod™ accessories including the Nerve Mapping Probe, Tri-Axial Accelerometer, and Stimulating Echogenic Nerve Block Needles
- Portable system suitable for veterinary anesthesia applications
Recommended Components for Basic Nerve Stimulation
| Component | Item # |
|---|---|
| STIMPOD™ Device | NB-STIM |
| Nerve Mapping Probe | NBMP |
| Stimulating Needle 22 Ga × 5 cm | NB2205 |
| Stimulating Needle 21 Ga × 8 cm | NB2108 |
| Stimulating Needle 21 Ga × 10 cm | NB2110 |
Accessory Comparison Guide
| Item # | Product | Purpose |
|---|---|---|
| NB-STIM | Stimpod™ Device | Nerve stimulation and neuromuscular monitoring platform |
| NBMP | Nerve Mapping Probe | Cutaneous nerve mapping and localization |
| NBCA | Tri-Axial Accelerometer | Objective measurement of muscle contraction strength during neuromuscular monitoring |
| NB2205 | Stimulating Echogenic Needle | Peripheral nerve localization and local anesthetic delivery |
| NB2108 | Stimulating Echogenic Needle | Peripheral nerve localization and local anesthetic delivery |
| NB2110 | Stimulating Echogenic Needle | Peripheral nerve localization and local anesthetic delivery |
Additional Information for the Nerve Mapping Probe
- Ergonomic cutaneous probe designed for noninvasive nerve mapping
- Activates Nerve Mapping/Locating mode on the Stimpod™
- Red (anode) connector designed to attach to a standard ECG electrode
- 2 mm needle connector accommodates stimulating needles and many third-party needle systems
- Additional Information for the Tri-Axial Accelerometer
- Provides objective measurement of muscle contraction strength
- Supports Train-of-Four, Double Burst, and Post-Tetanic Count monitoring modes
- Graphically displays measured contractions and calculated ratios
- Designed for use with standard ECG electrodes
- Additional Information for the Stimulating Echogenic Needles
- Designed for peripheral nerve block procedures
- Can be used with or without ultrasound guidance
- 360° echogenic tip improves ultrasound visibility
- Insulated cannula with stimulating tip for nerve localization
- Integrated injection port for local anesthetic administration
- 2 mm pin connector compatible with Stimpod™ and most nerve stimulators
- Centimeter markings facilitate precise depth placement